Sensing and measurement1028 — Flow Measurement

Matter Cluster 1028 — Flow Measurement

Matter Cluster 1028 (0x0404) Flow Measurement: attributes, commands, events, data types, shadow paths and bridge payload examples.

Matter Cluster 1028 — Flow Measurement Cluster

Matter Cluster 1028, also written as 0x0404, is the Flow Measurement Cluster. This cluster provides an interface to flow measurement functionality, including configuration and provision of notifications of flow measurements.

Cluster Identity

FieldValue
Cluster ID decimal1028
Cluster ID hex0x0404
Cluster nameFlow Measurement
Cluster revision (Matter 1.6.1)5
Roleapplication
ScopeEndpoint
PICS codeFLW
Typical endpoint1

Revision history

RevisionChange
1Mandatory global ClusterRevision attribute added
2CCB 2241 2370
3New data model format and notation
4Removed P quality
5Added F quality to MinMeasuredValue, MaxMeasuredValue and Tolerance attributes

Shadow Path Format

Cluster 1028 values in the device shadow use this format:

endpoint_id / 1028 / attribute_id

Example:

{
  "1/1028/0": 1
}
PartMeaning
1Endpoint ID
1028Flow Measurement cluster
0MeasuredValue attribute

Cluster 1028 Attributes

Cluster 1028 defines 4 attributes plus the global attributes. Conformance: M mandatory, O optional, a feature code means "mandatory when that feature is present", square brackets mean "optional when …".

IDHexAttributeTypeConformanceAccessQualitiesDefault
00x0000MeasuredValueuint16MR (read: view)nullable—
10x0001MinMeasuredValueuint16MR (read: view)nullable—
20x0002MaxMeasuredValueuint16MR (read: view)nullable—
30x0003Toleranceuint16OR (read: view)—0

Global attributes

IDHexAttributeMeaning
655280xFFF8GeneratedCommandListResponse command IDs this server generates.
655290xFFF9AcceptedCommandListCommand IDs this server accepts.
655310xFFFBAttributeListAttribute IDs implemented.
655320xFFFCFeatureMapImplemented optional features (see above).
655330xFFFDClusterRevisionCluster revision implemented; 5 for a Matter 1.6.1 device.

Attribute Details

Attribute 0 / 0x0000 — MeasuredValue

Path example:

1/1028/0

Indicates the flow in m^3/h as follows: MeasuredValue = 10 x Flow The null value indicates that the flow measurement is unknown, otherwise the range is as described in Measured Value.

PropertyValue
Typeuint16
ConformanceM
AccessR (read: view)
Qualitiesnullable
ConstraintMinMeasuredValue to MaxMeasuredValue

Example:

{
  "1/1028/0": 1
}

Attribute 1 / 0x0001 — MinMeasuredValue

Path example:

1/1028/1

Indicates the minimum value of MeasuredValue that can be measured. See Measured Value for more details. The null value indicates that the value is not available.

PropertyValue
Typeuint16
ConformanceM
AccessR (read: view)
Qualitiesnullable
Constraintmax 65533

Example:

{
  "1/1028/1": 1
}

Attribute 2 / 0x0002 — MaxMeasuredValue

Path example:

1/1028/2

Indicates the maximum value of MeasuredValue that can be measured. See Measured Value for more details. The null value indicates that the value is not available.

PropertyValue
Typeuint16
ConformanceM
AccessR (read: view)
Qualitiesnullable
Constraintmin compute

Example:

{
  "1/1028/2": 1
}

Attribute 3 / 0x0003 — Tolerance

Path example:

1/1028/3

See Measured Value.

PropertyValue
Typeuint16
ConformanceO
AccessR (read: view)
Constraintmax 2048
Default0

Example:

{
  "1/1028/3": 1
}

Cluster 1028 Commands

Cluster 1028 defines no commands. It is read (and, for writable attributes, written) through attribute access only.

Cluster 1028 Events

Cluster 1028 defines no events.


SmartphoneKey Notes

  • Cluster 1028 is not currently exposed by SmartphoneKey devices. This page documents the Matter 1.6.1 specification so that future devices can be interpreted without changes to the backend.
  • Shadow paths follow endpoint/1028/attribute; attribute values that the device reports as unreadable are written as n/a.
  • Attribute IDs, command IDs and enum values on this page come from the CSA Matter 1.6.1 data model; descriptions are condensed from the specification text.